1.5.7. Device – Sensor
It is setup for sensor in and out .
1. NO.
Sensor number on the DVR.
2. ON/OFF
Sensor On/Off.
3. CAMERA
the assigned camera setup with each sensor.
4. RELAY
the linked Relay setup with each sensor.
5. INTENSIVE
Intensive recording setup when sensor triggers. (Max. 30/25fps)
6. Preset
PTZ preset setup. If sensor triggers, the connected PTZ camera moves to preset location.
7. DWELL
Relay working period setup.
8. PRE-ALARM
Recording and camera popup period setup in seconds just before sensor triggers.
It links with motion alarm setting.
9. Type
Sensor type setup. (N/O: Normally Open, N/C: Normally Close)
10. NOTICE
Alarm notice type setup on the DVR. (Buzzer/Camera Popup)